Certificate
SGS Test Reports for MAISHI HDPE Rockshield
MAISHI HDPE rockshield pipeline protection mesh has been tested by SGS for tensile strength, tear strength, compressive strength and low-temperature flexibility down to -40 °C. The reports below cover the latest SGS test series (September 2026) and an earlier third-party tensile and impact test.
Verify every report with the issuing laboratory. Each report below is issued to HEBEI MAISHI WIRE MESH MANUFACTURE CO., LTD. If a supplier shows you one of these reports under a different company name, the laboratory record will reveal it. Report numbers and QR codes are left visible for this purpose.
Tensile Strength Test (ISO 10319:2024)
| Report No. | SZIN2609002661PL01_EN |
|---|---|
| Laboratory | SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch |
| Issue date | 2026-09-20 |
| Standard / method | ISO 10319:2024 wide-width tensile test |
| Key result | Transverse: 2.94 kN/m at 144.0 % strain. Lengthways: 8.17 kN/m at 54.6 % strain (5 specimens). |
| How to verify | Scan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail CN.Doccheck@sgs.com. |
| Full report | Request the complete report No. SZIN2609002661PL01_EN |
Tear Strength Test (ASTM D624)
| Report No. | SZIN2609002661PL04_EN |
|---|---|
| Laboratory | SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch |
| Issue date | 2026-09-16 |
| Standard / method | ASTM D624-00(2020), Type C specimen |
| Key result | MD: 5.3 kN/m. TD: 13.6 kN/m (specimen thickness 5.109 mm). |
| How to verify | Scan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail CN.Doccheck@sgs.com. |
| Full report | Request the complete report No. SZIN2609002661PL04_EN |
Compressive Strength Test (ASTM D1621)
| Report No. | SZIN2609002661PL06_EN |
|---|---|
| Laboratory | SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch |
| Issue date | 2026-09-23 |
| Standard / method | ASTM D1621-16 (Reapproved 2023) |
| Key result | Compressive stress at 10 % strain: 0.441 MPa (thickness direction). |
| How to verify | Scan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail CN.Doccheck@sgs.com. |
| Full report | Request the complete report No. SZIN2609002661PL06_EN |
Low-Temperature Bend Test at -40 °C (ASTM D2136)
| Report No. | SZIN2609002661PL07_EN |
|---|---|
| Laboratory | SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch |
| Issue date | 2026-09-23 |
| Standard / method | ASTM D2136-19ε1, 4 h conditioning, 3 mm mandrel |
| Key result | -40 °C for 4 h: 3 of 3 specimens passed, no cracking under 5x magnification. |
| How to verify | Scan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail CN.Doccheck@sgs.com. |
| Full report | Request the complete report No. SZIN2609002661PL07_EN |
Tensile, Elongation and Impact Test (HBMS-800)
| Report No. | DB-20130605-004 |
|---|---|
| Laboratory | Qingdao Dongbiao Testing Service Co., Ltd. |
| Issue date | 2013-07-10 |
| Standard / method | ISO 10319-2008; GB/T 1732-1993 (impact) |
| Key result | Warp: 10.9 kN/m, 65 % elongation. Weft: 8.9 kN/m, 73 % elongation. Impact resistance: 47 kg·cm. |
| How to verify | Contact the issuing laboratory and quote the report number. |
| Full report | Request the complete report No. DB-20130605-004 |
Only the cover page and one results page of each report are shown online. The complete original report is sent on request after an inquiry, as a view-only link or as a PDF issued to your company name.